a b c d e f g h i j k
l
m
n o p q r
2℃
42
34
32
30
OFF
ON
1'
2'
58''
30
SLO SLO LO-
SSLO
SSLO
SSLO
SSLO
30'
150'
Indoor heat
exchanget
Temp.
Intake Temp.
Basic Time
Compressor
Indoor Fan
Outdoor Fan
Operation Indicator
4-way valve
Automatic Fan Speed
During Heating Operation, use remote controller to select Auto Fan Speed mode.
Indoor Fan Speed is between Me and Slo.
Me
Lo
Lo-
S Lo
()
(
)
45
41
34
30
38
30
28
15
Temperature of heat exchanger
Stop
Time
Time Graph for Heating Operation
Warm booting control(indoor fan Off)
Warm booting control(indoor fan Super Slo)
Prevent cool air blowing out
a-b
c- d
h-k, o-r
:
:
:
<Operation status>
Blink
Operate
Stop
Manual fan speed