CUTTING AND FLARING THE PIPING
1. Please cut using pipe cutter and then remove the burrs.
2. Remove the burrs by using reamer. If burrs is not
removed, gasleakage maybecaused.
Turn the piping end downtoavoid the metalpowder
entering the pipe.
3. Please make flare after inserting the flare nut onto the
copper pipes.
9.3.4. (a)EVACUA TION OF THE EQUIPMENT (FOR EUROPE & OCEANIA DESTINATION)
WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in the
following procedure.
1. Connect a charging hose with a push pin to the Low side ofacharging set and the service port of the 3-wayvalve.
ı
ıı
ıˇı
ˇıˇı
ˇı
Be sure to connect the end of the charging hose with the push pin to the service port.
2. Connect the center hose of the charging set to a vacuum pump with check valve, or vacuum pump and vacuum pump adaptor.
3. Turn on the power switch of the vacuu
m pump and make sure that the needle in the gauge moves from 0cmHg (0 MPa)to
-76 cmHg (-0.1 MPa). Then evacuate the air approximately ten minutes.
4. Close the Low side valve of the charging set and turn off the vacuum pump. Make sure that the needle in the gauge does not
move after approximately five minutes.
Note: BE SURE TO FOLLOW THIS PROCEDURE IN ORDER TO AVOID REFRIGERANT GAS LE
AKAGE.
5. Disconnect the charging hose from the vacuum pump and from the service port of the 3-wayvalve.
6. Tighten the service port caps of the 3-wayvalve at torque of 18 N.mwith a torque wrench.
7. Remove the valve caps of both of the 2-wayvalve and 3-wayvalve. Position both of the valves to “OPEN” usingahexagonal
wrench (4 mm).
8. Mount va
lve caps onto the 2-wayvalve and the 3-wayvalve.
ı
ıı
ıˇı
ˇıˇı
ˇı
Be sure to checkfor gasleakage.
CAUTION
ı
ıı
ıˇı
ˇıˇı
ˇı
Ifgauge needle does not move from 0cmHg (0 MPa )to-76 cmHg (-0.1 MPa ), in step 3 above take the followingmeasure:
ı
ıı
ıˇı
ˇıˇı
ˇı
If the leak stops when the piping connections are tightened further, continue workingfrom step 3.
ı
ıı
ıˇı
ˇıˇı
ˇı
If the leak does not stop when the connections are retightened, repa ir the location of leak.
ı
ıı
ıˇı
ˇıˇı
ˇı
Do not release refrigerant during pipingworkfor installation and reinstallation. Takecare of the liquid ref rigerant, it maycause
frostbite.