47
11.6 Powerful Mode Operation
When the powerful mode is selected, the internal setting temperature will shift lower up to 2°C (for Cooling/Soft
Dry) than remote control setting temperature for 240 minutes and the fan speed will increase to achieve the
setting temperature quickly.
Powerful operation stops condition
o When one of the following condition is satisfied, powerful operation stops:
Eco Patrol button is pressed.
Quiet button is pressed.
Mild Dry Cooling button is pressed.
Stop by OFF/ON button.
OFF Timer activates.
Powerful button is pressed again.
Powerful operation continue for 240 minutes.
11.7 Timer Control
There are 2 sets of ON and OFF timer is available to turn the unit ON or OFF at different preset time.
If more than one timer had been set, the upcoming timer will be display and will activated in sequence.
11.7.1 ON Timer Control
ON Timer 1 and ON Timer 2 can be set using remote control, where the unit with timer set will start operation earlier
than the setting time. This is to provide a comfortable environment when reaching the set ON time.
60 minutes before the set ON time, indoor (at fan speed of Lo-) and outdoor fan motor start operation for 30 seconds
to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting
time.
From the above judgment, the decided operation will start operation earlier than the set time as shown below.
11.7.2 OFF Timer Control
OFF Timer 1 and OFF Timer 2 can be set using remote control, where the unit with timer set will stop at set OFF time.
Notes:
1 By pressing ON/OFF operation button, the ON Timer or OFF Timer setting will not be cancelled.
2 To cancel the previous timer setting, press CANCEL button.
3 To activate the previous timer setting, press SET button.
4 If main power supply is switched off, the Timer setting will be cancelled.
11.8 Random Auto Restart Control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes. There are 10 patterns to be selected randomly after power supply resumes.
This control is not applicable during OFF/ON Timer setting.
15 min
10 min
5 min
Indoor intake air
tem
p
erature
(
°C
)
30
25
30 35
Outdoor air
tem
p
erature
(
°C
)
Coolin
g
/ Soft Dr
y

Table of Contents