50
Indicator
o When patrol is selected, patrol sensor indicator ON.
Remote Control Receiving Sound
o Normal Operation Î Patrol Mode : Beep
o Patrol Mode Î Stop : Long Beep
o Patrol Mode Î Normal Operation : Beep
o Stop Î Patrol : Beep
Timer Control
o When ON timer activates when unit stops, previous operation resumes and restored last saved Patrol
operation status.
o When ON timer activates during any operation, no change and carry on current operation.
o When OFF timer activates during any operation, all operation stops and the latest Patrol operation status is
saved.
Power Failure Control
o During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation
resumes immediately.
o During combination operation, if power failure occurs, after power resumes combination operation resume
immediately.
Patrol Operation Demo Mode
o Patrol Operation Demo Mode start condition
Press “Set” button continuously for 15 seconds by using pointer during Air Conditioner is OFF condition
to enter internal setting mode.
Press “Timer Decrement” button to select “Pt demo”.
Press “Timer Set” button to toggle Patrol operation demo mode.
Long “beep”: Turn OFF Patrol operation demo mode.
Short “beep”: Turn ON Patrol operation demo mode.
NO Description BLUE ORANGE RED E-ION
1 When patrol function is not selected OFF OFF OFF -
2 During gas sensor error detection control OFF OFF Blinking OFF
3 During stop OFF OFF OFF OFF
4 2 minutes gas sensor initial stabilization time (Level 0) ON OFF OFF OFF
a. Dirtiness level 0* ON OFF OFF OFF
b. Dirtiness level 1 OFF ON OFF OFF
c. Dirtiness level 1* OFF ON OFF ON
5 During operation
During patrol
d. Dirtiness level 2 OFF OFF ON ON