34
12.8. Auto Restart Control
1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four
minutes there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly. After power
supply resumes.
2. This type of control is not applicable during ON/OFF Timer setting.
12.9. Indication Panel
Note:
If POWER LED blinks, the possible operation of the unit is operation mode judgment, or ON timer sampling.
If Timer LED blinks, there is an abnormal operation occurs.
If e-ion LED blinks, there is an abnormal e-ion operation occurs.
If PATROL LED blinks, there is gas sensor error detection.
12.10. Patrol Operation
To monitor air dirtiness level by using Patrol sensor and to maintain air freshness by activates e-ion operation.
Patrol operation starts condition
- When the unit operation is started with “OFF/ON” button.
- When the unit stops, “Patrol” button is pressed, Patrol individual operation will start.
- During cooling only operation, “Patrol” button is pressed.
LED POWER TIMER QUIET POWERFUL e-ion PATROL
Color Green Orange Orange Orange Blue Blue Orange Red
Light ON Operation ON Timer Setting ON Quiet Mode ON
Powerful Mode
ON
e-ion ON Air Clean Moderate Dirty
Light OFF Operation OFF Timer Setting OFF Quiet Mode OFF
Powerful Mode
OFF
e-ion OFF PATROL OFF