- Active e-ion Air Purifying system breakdown error:
Q Judgment Method
When hi-feedback voltage (at microcontroller) supplied to filter during e-ion stop, active e-ion Air Purifying system
breakdown error shows immediately.
It is due to indoor PCB or filter’s high voltage power supply damage.
Operations except e-ion continue. Both Timer indicator and e-ion indicator blink.
Q Troubleshooting Method
Press “e-ion” button or “OFF/ON” button to stop the operation.
Change main circuit board or filter’s high voltage power supply.
When lo-feedback voltage supplied to active e-ion Air Purifying system during e-ion operation, e-ion indicator and
Timer indicator stop blinking.