EasyManuals Logo

Panasonic CS-S18HKQ User Manual

Panasonic CS-S18HKQ
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
46
15.1.1. Relationship between the condition of the air conditioner and pressure and electric
current
Carry out the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started.
Cooling Mode
Low Pressure High Pressure
Electric current during
operating
Condition of the air
conditioner
Insufficient refrigerant
(gas leakage)
Clogged capillary tube
or Strainer
Short circuit in the
indoor unit
Heat radiation deficiency
of the outdoor unit
Inefficient compression

Table of Contents