25
How to retrieve error codes
If the unit stops and the TIMER indicator blinks, use the remote control to retrieve the error code.
Press until you hear beep sound
(about 4 seconds), then write down
the error code
2
1
Press for
5 seconds
Press for
5 seconds to
quit checking
3
Turn the unit off and reveal the error
code to authorised dealer
4
•
For certain errors, you may restart the unit for limited operation if there are 4 beeps when operation starts.
* Some error code may not be applicable to your model. Consult authorised dealer for clarification.
Diagnostic
display
Abnormality/Protection
control
H 00 No memory of failure
H 11
Indoor/outdoor abnormal
communication
H 14
Indoor intake air temperature sensor
abnormality
H 15
Outdoor compressor temperature
sensor abnormality
H 16
Outdoor current transformer (CT)
abnormality
H 19 Indoor fan motor mechanism lock
H 23
Indoor heat exchanger temperature
sensor abnormality
H 27
Outdoor air temperature sensor
abnormality
H 28
Outdoor heat exchanger temperature
sensor abnormality
H 33 Abnormal voltage
H 59 Human activity sensor abnormality
H 67 nanoe abnormality
Diagnostic
display
Abnormality/Protection
control
H 70 Sunlight sensor abnormality
H 97 Outdoor fan motor mechanism lock
H 98 Indoor high pressure protection
H 99
Indoor operating unit freeze
protection
F 90
Power factor correction (PFC) circuit
protection
F 91 Refrigeration cycle abnormality
F 93
Outdoor compressor abnormal
revolution
F 95
Outdoor cooling high pressure
protection
F 96
Power transistor module overheating
protection
F 97 Compressor overheating protection
F 98 Total running current protection
F 99
Outdoor direct current (DC) peak
detection
Troubleshooting