EasyManua.ls Logo

Panasonic CS-U71XKR - To Learn More...; Understanding Operation Modes; Energy Saving Temperature Settings; Airflow Direction Details

Panasonic CS-U71XKR
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
To Learn More...
Operation mode
AUTO : The POWER indicator blinks at the initial stage.
COOL : Provides ef cient comfort cooling to suit your needs.
DRY : Operates at low fan speed for a gentle cooling operation.
FAN : To circulate air in the room.
Energy saving temperature setting
You may save energy when operating the unit within the recommended temperature range.
COOL : 26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F.
Air ow direction
In COOL/DRY mode:
The horizontal ap swings up/down automatically.
Once the temperature is achieved, the horizontal ap is xed at upper position.
In COOL/DRY mode:
The horizontal ap swings up/down automatically.
Auto restart control
When power is resumed after a power failure, the operation will restart automatically with the
last operation mode and air ow direction.
This control is not applicable when TIMER is set.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 (89.6) 23 (73.4) 46 (114.8) 26 (78.8)
Min. 16 (60.8) 11 (51.8) 5 (41.0) -
DBT: Dry bulb temperature, WBT: Wet bulb temperature