Cleaning instructions
To ensure optimal performance of the unit,
cleaning has to be carried out at regular intervals.
Dirty unit may cause malfunction and you may
see error code “H99”. Please consult authorised
dealer.
Switch off the power supply and unplug before
cleaning.
Do not touch the aluminium n, sharp parts may
cause injury.
Do not use benzine, thinner or scouring powder.
Use only soap (
pH 7) or neutral household
detergent.
Do not use water hotter than 40 °C.
Indoor unit
Wipe the unit gently with a soft,
dry cloth.
Front panel
Wash gently and dry.
Remove the front panel
POWER
TIMER
POWERFUL
QUIET
Raise
1
Pull out
2
Close it securely
1
Insert at both sides
POWER
TIMER
POWERFUL
QUIET
2
Close down
3
Press both ends of the front panel
4
Press at center of the front panel
POWER
TIMER
POWERFUL
QUIET
Aluminium finFront panel
Air filters
Indoor unit
Air Purifying Filter
Air lters
Every 2 weeks
• Wash/rinse the lters gently with
water to avoid damage to the lter
surface.
• Dry the lters thoroughly under shade, away from
re or direct sunlight.
Replace any damaged lters.
Remove air lter Attach air lter
Insert into the unit
Air Purifying Filter
Air Purifying Filter
Do not wash the air purifying lter.
• Replace the lter every 10 years or replace any
damaged lter. Part no.: CZ-SA32P
For seasonal inspection after extended non-
use
Checking of remote control batteries.
No obstruction at air inlet and air outlet vents.
Use Auto OFF/ON button to select COOL/
HEAT operation. After 15 minutes of operation,
it is normal to have the following temperature
difference between air inlet and air outlet vents:
COOL: 8 °C
HEAT: 14 °C
For extended non-use
Activate HEAT mode for 2~3 hours to remove
moisture left in the internal parts thoroughly to
prevent mould growth.
Turn off the power supply and unplug.
Remove the remote control batteries.

Other manuals for Panasonic CS-UE18RKE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-UE18RKE and is the answer not in the manual?

Panasonic CS-UE18RKE Specifications

General IconGeneral
TypeAir conditioner indoor unit
IonizerNo
Multi-split-
Product colorWhite
Hose length (max)15 m
Inverter technologyYes
Dehumidifying capacity2.8 l/h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (max)5600 W
Cooling capacity in watts (min)980 W
Heating capacity in watts (max)7700 W
Cooling capacity in watts (nominal)5000 W
Cooling energy efficiency (EER, W/W)3.25
Heating energy efficiency (COP, W/W)3.67
Operating temperature (cooling) (T-T)5 - 43 °C
Operating temperature (heating) (T-T)-10 - 24 °C
Seasonal efficiency rating (cooling) (SEER)6.5
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)5400 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4.3
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)5 kW
Energy efficiency class (cooling)A++
Power consumption (cooling) (max)1750 W
Power consumption (cooling) (min)285 W
Power consumption (heating) (max)2300 W
Power consumption (heating) (min)350 W
Annual energy consumption (cooling)269 kWh
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)4 kW
Energy efficiency class (heating) (Average heating season)A+
Annual energy consumption (heating) (Average heating season)1302 kWh
Indoor unit typeWall-mountable
Indoor unit depth240 mm
Indoor unit width1070 mm
Indoor unit height290 mm
Indoor unit weight12000 g
Indoor units quantity1
Cooling airflow (indoor unit)978 m³/h
Heating airflow (indoor unit)1074 m³/h
Indoor unit noise level (high speed)44 dB
Outdoor unit noise level- dB