Refrigerant Control Device Capillary Tube
Refrigeration Oil (cm
3
) FVC68D (330)
Refrigerant (R-410A) g (oz) 950 (33.5)
Thermostat Electronic Control
Protection Device 2 Stage Overload Protector
Capillary Tube Length mm 803
Flow Rate l/min 8.5
Inner Diameter mm 1.4
Air Filter Material
Style
P.P.
Honeycomb
Capacity Control Capillary Tube
Compressor Capacitor µF, VAC 30 µF, 370VAC
Fan Motor Capacitor µF, VAC 1.5 µF, 400VAC 2.0 µF, 450VAC
Specifications are subject to change without notice for further improvement.