Heat Exchanger Description Evaporator Condenser
Tube material Copper Copper
Fin material Aluminium Aluminium
Fin Type Slit Fin Louver Fin
Row / Stage (Plate fin configuration, forced draft)
(A) 2 × 15 (B) 2 × 15 2×24
FPI 21 19 14
Size (W × H × L) mm 610 × 315 × 25.4 756
719.5
× 609.6 × 44
Refrigerant Control Device Capillary Tube
Refrigeration Oil (c.c) SUNISO 4GDID or ATMOS
M60 (330, 330)
Refrigerant (R410A) g(oz) (A) 1,050 (37.0)
(B) 860 (30.3)
Thermostat Electronic Control
Protection Device Overload Protector
Capillary Tube Length mm (A) 1,160 (B) 810
Flow Rate l/min (A) 10.5 (B) 7.0
Inner Diameter mm (A) 1.6 (B) 1.3
Air Filter Material
Style
(c.c) P.P.
Honeycomb
Capacity Control Capillary Tube
Compressor Capacitor µF, VAC (A) 35 µF, 370 VAC
(B) 25 µF, 370 VAC
Fan Motor Capacitor µF, VAC 1.5 µF, 400 VAC 3.0 µF, 450 VAC
Specifications are subject to change without notice for further improvement.