FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• After 15 minutes of operation, it is normal to have the following
temperature difference between air inlet and air outlet vents:
Cooling: ≥ 8°C
FOR EXTENDED NON-USE
• Activate nanoe-G operation for 2~3 hours as an alternative to
remove moisture left in the internal parts thoroughly to prevent
mould growth.
• Turn off the power supply and unplug.
• Remove the remote control batteries.
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY AND UNPLUG
then please consult authorized dealer under the
following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote
control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
Information for Users on Collection and Disposal of Old Equipment and used Batteries
[Information on Disposal in other Countries
outside the European Union]
These symbols are only valid in the European
Union. If you wish to discard these items, please
contact your local authorities or dealer and ask for
the correct method of disposal.
Note for the battery symbol
(bottom two symbol examples):
This symbol might be used in
combination with a chemical symbol.
In this case it complies with the
requirement set by the Directive for the
chemical involved.
Pb
NOTES
NANOE-G
,
OWERFUL
QUIET
• Can be activated in all modes and can be cancelled
by pressing the respective button again.
OWERFUL
QUIET
• Cannot be selected at the same time.
7
TO PURIFY THE AIR
NANOE-G
• Removes/deactivates harmful micro-organisms such as
viruses, bacteria, etc.
• Can be activated even when the unit is turned off. In this
condition, fan speed and air swing cannot be adjusted.
• nanoe-G starts automatically with the unit switched on
with
OFF/ON
.
8
TO SWITCH BETWEEN
POWERFUL & QUIET
POWERFUL/QUIET
POWERFUL/
QUIET
QUIETPOWERFUL NORMAL
P
WERFUL
TO REACH TEMPERATURE QUICKLY
• This operation will stop automatically after 15
minutes.
UIET
TO ENJOY QUIET OPERATION
• This operation reduces airfl ow noise.
9
Press and hold for 5 seconds to dim or restore the
unit’s indicator brightness.
10
Press and hold for approximately 10 seconds to
show temperature setting in °C or °F.
11
Not used in normal operations.
12
Press to restore the remote control’s default setting.
TO SET THE TIMER
• To turn ON or OFF the unit at a preset time.
ON
OFF
1
2
TIMER
ET
Select ON or
OFF timer
Set the time Confi rm
• To cancel ON or OFF timer, press
N
or
OFF
then
press
CANCEL
.
• When ON Timer is set, the unit may start earlier (up
to 15 minutes) before the actual set time in order to
achieve the desired temperature on time.
• Timer operation is based on the clock set in the
remote control and repeats daily once set. For clock
setting, please refer to Remote Control Preparation
on the back cover.
• If timer is cancelled manually or due to power failure,
you can restore the previous setting (once power is
resumed) by pressing
SET
.