81 
  To limit set temperature range for iCOMFORT, COOL & DRY mode. 
o  Press “Set” button by using pointer. 
o  Press TEMP increment or decrement button to choose No. 3. 
o  Press Timer increment or decrement button to select desired temperature low limit of set temperature for 
iCOMFORT, COOL & DRY mode. 
 
iCOMFiAUTO-XHEATCOOLDRYFAN
F
SHOWER
DIRE CT
AM
PM
AM
ON
OFF
PM
Memorize new
Low2 range
Normal display mode
Press SW to enter customer zone &
Press SW’s to choose function 3
Press SW to comfirm selection
Use SW or SW to change Low2 range
SET
i)  Display latest set temp (Low2).
ii) After reset, Low2 = 16°C (by default)
Range = 16°C ~ [High2]
No code transmission
 
 
o  Press Timer Set button to confirm low limit selection. 
o  Press TEMP increment or decrement button to choose No. 4. 
o  Press Timer decrement or increment button to select desired temperature high limit of set temperature for 
iCOMFORT, COOL & DRY mode. 
 
iCOMFiAUTO-XHEATCOOLDRYFAN
F
SHOWER
DIRE CT
AM
PM
AM
ON
OFF
PM
Memorize new
High2
 range
Normal display mode
Press SW to enter customer zone &
Press SW’s to choose function 4
Press SW to comfirm selection
Use SW or SW to change High2 range
SET
i)  Display latest set temp (High2).
ii) After reset, High2 = 30°C (by default)
Range = [Low2] ~ 30°C
No code transmission
 
 
o  Press Timer Set button to confirm high limit selection. 
o  LCD returns to original display if remote control does not operate for 30 seconds or press Timer Cancel 
button.