168
19. Technical Data
Technical data provided are based on the air conditioner running under free frequency.
19.1 Cool Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Cool mode at 16°C
Voltage: 230V
19.1.1 CS-VZ9SKE CU-VZ9SKE
Indoor (°C) Outdoor DB (°C)
DB WB
16 25 35
TC SHC IP TC SHC IP TC SHC IP
27
19.0 2.99 2.66 0.24 2.81 2.53 0.33 2.50 2.40 0.43
22.0 3.40 2.07 0.23 3.16 1.96 0.32 2.78 1.81 0.43
23
15.7 2.70 2.57 0.24 2.63 2.47 0.32 2.35 2.30 0.43
18.4 3.05 2.04 0.22 2.80 1.93 0.31 2.59 1.78 0.42
20
13.3 2.18 2.14 0.23 2.11 2.07 0.32 1.85 1.81 0.42
15.8 2.40 1.73 0.20 2.30 1.68 0.29 2.09 1.61 0.40
19.1.2 CS-VZ12SKE CU-VZ12SKE
Indoor (°C) Outdoor DB (°C)
DB WB
16 25 35
TC SHC IP TC SHC IP TC SHC IP
27
19.0 4.186 3.726 0.446 3.93 3.54 0.606 3.50 3.36 0.800
22.0 4.76 2.904 0.422 4.43 2.75 0.595 3.89 2.53 0.792
23
15.7 3.784 3.594 0.442 3.68 3.46 0.600 3.29 3.22 0.792
18.4 4.271 2.862 0.412 3.92 2.70 0.582 3.62 2.50 0.780
20
13.3 3.056 2.995 0.433 2.95 2.89 0.588 2.59 2.54 0.776
15.8 3.357 2.417 0.372 3.23 2.35 0.536 2.92 2.25 0.745
TC - Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP - Input Power (kW)