12.2.3  Indoor Unit Installation 
 
Do not turn over the unit without it’s shock absorber during pull out the piping. It may cause intake grille damage.
Use shock absorber during pull out the piping to protect the intake grille from damage.
Piping
Shock absorber
Intake grille
Piping
 
12.2.3.1  For the right rear piping 
 
Pull out the Indoor piping
Install the Indoor Unit
Secure the Indoor Unit
Insert the connection cable
 
12.2.3.2  For the right and right bottom 
piping 
 
Pull out the Indoor piping
Install the Indoor Unit
Insert the connection cable
Secure the Indoor Unit
 
12.2.3.3  For the embedded piping 
 
Replace the drain hose
Bend the embedded piping
Pull the connection cable into Indoor Unit
Cut and flare the embedded piping
Install the Indoor Unit
Connect the piping
Insulate and finish the piping
Secure the Indoor Unit
Use a spring bender or equivalent to bend the piping
so that the piping is not crushed.
The inside and outside connection cable can be
connected without removing the front grille.
When determining the dimensions of the piping, slide
the unit all the way to the left on the installation plate.
Refer to the section “Cutting and flaring the piping”.
Please refer to “Insulation of piping connection” column
as mentioned in indoor/outdoor unit installation.
Please refer to “Connecting the piping” column in
outdoor unit section. (Below steps are done after
connecting the outdoor piping and gas-leakage
confirmation).
 
 
 
 
 
 
 
 
Install the indoor unit
Secure the Indoor Unit
Right Rear piping
Right and Right Bottom piping
Cover for the 
bottom piping
Cover for the 
bottom piping
Tape it with piping 
in a position as 
mentioned in Fig. 
below.
Cover for the
right piping 
Piping
Drain 
hose
Cover for the 
left piping 
Cover for piping
In case of the cover is cut, 
keep the cover at the rear 
of chassis as shown in 
the illustration for future 
reinstallation.
(Left, right and 2 bottom 
covers for piping.)  
How to keep the cover
Cover for 
the bottom 
piping
Tape it with piping  
in a position as
mentioned in Fig. 
below.
Cover for 
the right 
piping
Piping
Drain hose
Cover for the 
left piping
Drain hose
Sleeve for 
piping hole
Indoor unit
Hooks at 
installation 
plate
Piping
Hook the indoor unit onto the upper 
portion of installation plate. 
(Engage the indoor unit with the 
upper edge of the installation plate). 
Ensure the hooks are properly 
seated on the installation plate by 
moving it in left and right.
1. Press the lower left and right side 
of the unit against the installation 
plate until hooks engages with 
their slot (sound click).
Installation 
plate
Unit’s 
hook
To take out the unit, push the 
            marking at the bottom 
unit, and pull it slightly towards 
you to disengage the hooks 
from the unit. 
 marking
Guide 
surface
Connection cable
About
70 – 80 mm
Connection 
cable
Gas side piping
Liquid side piping
Drain hose
Insert the connection cable
PUSH
PUSH
 
 
(This can be used for left rear piping and bottom 
piping also.)