EasyManua.ls Logo

Panasonic CS-W50BTP

Panasonic CS-W50BTP
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13 SAFETY DEVICE
INDOOR UNIT
Heat pump model
Indoor unit CS-W50BTP
Cooling only model
For Fan Motor Protection, OFF °C 135
Internal Protector (49F) ON °C 85
For Control Protection, Fuse CUT A 3.15
OUTDOOR UNIT
Outdoor Unit Heat pump model 50Hz CU- W50BBP8
Cooling
only
model
50Hz CU- V50BBP8
60Hz -
For Refrigerant Cycle, OFF MPa
(*1)
3.1
High Pressure Switch (63H
1
) ON MPa
(*1)
2.3
For OFF A 15
Compressor (Heat pump)
Over Current OFF A 15
Protection (Cooling 50Hz
only) A -
60Hz
RESET - Automatic
Discharge Temp. Compressor °C 120
Protection, OFF
Discharge Temp.
Thermistor (Th1)
Liquid Compression Protection, Crankcase
Heater
Input power W 34~41
Compressor
Protection,
OFF °C
50Hz
145
Internal
Protector
°C
60Hz
-
ON °C
50Hz
61
°C
60Hz
-
Trip time 50Hz 3-10sec/ 48A
60Hz -
For Fan Motor Protection, OFF °C 135
Internal Protector (49F) ON °C 85
Heating Control Pressure Switch (Heat
pump only) (Fan speed) (63H
2
)
OFF MPa
(*1)
2.50
ON MPa
(*1)
2.05
Cooling Control, Heat Exchanger Outlet Temp.
Thermistor (Th2)
Control method
Th 30 degree celcius ----- High speed
Th < 30 degree celcius ------5 speed step control
For Control Protection, Fuse CUT A 6.3
(*1) 1MPa = 10.2 kgf/cm
2
(*2) Head Thermostat only for W/V28BBP8 & V24BBP8