17
Indoor Model CS-XE24WKUAW
Outdoor Model CU-XE24WKUA
Performance Test Condition ARI
Power Supply
Phase, Hz Single, 60
V 208 230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 1.70 7.02 8.00 1.70 7.02 8.00
BTU/h 5800 24000 27200 5800 24000 27200
Running Current A - 11.10 - - 10.10 -
Input Power W 380 2.20k 2.52k 380 2.20k 2.52k
EER
W/W 4.47 3.19 3.17 4.47 3.19 3.17
BTU/hW 15.25 10.90 10.75 15.25 10.90 10.75
Power Factor % - 95 - - 95 -
Indoor Noise (H / L / QLo)
dB-A 49 / 40 / 37 49 / 40 / 37
Power Level dB 65 / - / - 65 / - / -
Outdoor Noise (H / L / QLo)
dB-A 53 / - / - 53 / - / -
Power Level dB 67 / - / - 67 / - / -
Heating
Capacity
kW 1.70 8.46 9.90 1.70 8.46 9.90
BTU/h 5800 28800 33800 5800 28800 33800
Running Current A - 12.80 - - 11.50 -
Input Power W 380 2.52k 3.00k 380 2.52k 3.00k
COP
W/W 4.47 3.36 3.30 4.47 3.36 3.30
BTU/hW 15.25 11.40 11.25 15.25 11.40 11.25
Power Factor % - 95 - - 95 -
Indoor Noise (H / L / QLo)
dB-A 49 / 40 / 37 49 / 40 / 37
Power Level dB 65 / - / - 65 / - / -
Outdoor Noise (H / L / QLo)
dB-A 55 / - / - 55 / - / -
Power Level dB 69 / - / - 69 / - / -
17°F: Rated Capacity (BTU/h) / I. Power (W) 18500 / 2.05k
5°F: Max. Capacity (BTU/h) 25200 / 2.07
Max Current (A) / Max Input Power (W) 15.6 / 3.44k
Starting Current (A) 12.80
Compressor
Type Hermetic Motor (Rotary)
Motor Type Brushless (4-poles)
Output Power W 1.70k