Why does my Panasonic CS-Z71VKR Air Conditioner outdoor unit emit water or steam?
- Cchristy36Sep 12, 2025
The emission of water or steam from the outdoor unit is due to condensation or evaporation occurring on the pipes.
Why does my Panasonic CS-Z71VKR Air Conditioner outdoor unit emit water or steam?
The emission of water or steam from the outdoor unit is due to condensation or evaporation occurring on the pipes.
Why is my Panasonic CS-Z71VKR remote control not working?
If your Panasonic Air Conditioner remote control isn't working, ensure the batteries are inserted correctly. If the display is dim or the transmission signal is weak, try replacing the batteries with new ones.
Why is the TIMER indicator always on on my Panasonic CS-Z71VKR?
The timer setting repeats daily once set.
Why is my Panasonic CS-Z71VKR Air Conditioner making a louder noise at the outdoor unit during early operation of i AUTO-X?
The compressor and fan rotate at a higher speed to boost cooling performance during initial operation.
Why does the POWER indicator blink on my Panasonic Air Conditioner before it's switched on?
The blinking POWER indicator is a preliminary step in preparation for operation when the ON timer has been set. When the ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time.
Why does airflow continue after I stop my Panasonic CS-Z71VKR?
The airflow continues even after operation has stopped because the unit is extracting remaining heat from the indoor unit, which can take up to 30 seconds.
Why is my Panasonic CS-Z71VKR Air Conditioner making a cracking sound during operation?
The cracking sound during operation is caused by changes in temperature, leading to the expansion or contraction of the unit.
Why does my Panasonic CS-Z71VKR make a water flowing sound during operation?
The water flowing sound you hear during operation is due to the refrigerant flow inside the unit.
Why is there a delay after restarting my Panasonic Air Conditioner?
The delay is a protection mechanism for the unit’s compressor.
Why does mist emerge from my Panasonic Air Conditioner indoor unit?
The mist emerging from the indoor unit is a condensation effect due to the cooling process.
Cooling Capacity | 7.1 kW |
---|---|
Heating Capacity | 8.0 kW |
Seasonal Energy Efficiency Ratio (SEER) | 6.10 |
Weight (Outdoor Unit) | 48 kg |
Energy Efficiency Class Cooling | A++ |
Energy Efficiency Class Heating | A+ |
Refrigerant | R32 |
Power Supply | 220-240 V, 50 Hz |
Safety guidelines for indoor units, outdoor units, remote controls, and power supply.
Precautions for operating indoor/outdoor units, including cleaning and specific conditions.
Critical safety information regarding the use and handling of R32 refrigerant.
Key requirements for the safe installation of the air conditioner unit.
Ensuring safety during piping installation and maintenance to prevent leaks or damage.
Guidelines for qualified personnel performing maintenance and repairs.
Procedures for checking refrigerant leaks and maintaining a fire-safe environment.
Ensuring proper ventilation and conducting electrical safety checks.
Safety measures for repairing unit components and inspecting cabling.
Acceptable methods for detecting flammable refrigerants and leak detection.
Safe procedures for removing and charging refrigerant in the system.