EasyManua.ls Logo

Panasonic CU-2TZ41TBE - Page 17

Panasonic CU-2TZ41TBE
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature
°C (°F)
Indoor
Single split outdoor unit
*
1
Multi split outdoor unit *
2
DBT WBT DBT WBT DBT WBT
COOL
Max. 32 (89.6) 23 (73.4) 43 (109.4) 26 (78.8) 46 (114.8) 26 (78.8)
Min. 16 (60.8) 11 (51.8) -10 (14.0) - -10 (14.0) -
HEAT
Max. 30 (86.0) - 24 (75.2) 18 (64.4) 24 (75.2) 18 (64.4)
Min. 16 (60.8) - -15 (5.0) -16 (3.2) -15 (5.0) -16 (3.2)
DBT: Dry bulb temperature, WBT: Wet bulb temperature
*
1
CU-TZ20ZKE, CU-TZ25ZKE, CU-TZ35ZKE, CU-TZ42ZKE, CU-TZ50ZKE, CU-RZ25ZKE, CU-RZ35ZKE, CU-RZ50ZKE
*
2
CU-2Z35TBE, CU-2Z41TBE, CU-2Z50TBE, CU-3Z52TBE, CU-3Z68TBE, CU-4Z68TBE, CU-4Z80TBE, CU-5Z90TBE,
CU-2TZ41TBE, CU-2TZ50TBE, CU-3TZ52TBE