2
Multi air conditioner system
Multi air conditioner systems save space by
letting you connect multiple indoor units to a
single outdoor unit.
For complete product features, please refer
catalogue.
Indoor units
It is possible to operate the indoor units
individually or simultaneously. The priority
of operation is placed on the rst unit that
turned on.
During operation, HEAT and COOL modes
cannot activate at the same time for
different indoor units.
The power indicator blinks to indicate the
indoor unit is standing by for a different
operation mode.
Outdoor unit
Indoor units
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Single split outdoor unit
CU-E9SB4R
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 23 46 26
Min. 16 11 5 -
HEAT
Max. 30 - 24 18
Min. 16 - -15 -
°C (temperature)
Multi split outdoor unit
CU-2E18SBR, CU-3E18SBR,
CU-4E23QBR, CU-4E27QBR,
CU-5E32QBR
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 23 46 26
Min. 16 11 -10 -
HEAT
Max. 30 - 24 18
Min. 16 - -15 -16
°C (temperature)