178
18.1.8 CU-E28NKR
Cooling Characteristic
[Condition] Indoor temperature: 27/19°C
Remote condition: High fan speed
Comp. Hz: F
c
Piping Length: 5m
10.700
11.200
11.700
12.200
12.700
13.200
13.700
14.200
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
Outdoor Air Temperature (°C)
Outlet Air
Temperature (°C
)
230 240
6.100
6.600
7.100
7.600
8.100
8.600
9.100
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
Outdoor Air Temperature (°C)
Cooling
Capacity (kW)
7.900
8.400
8.900
9.400
9.900
10.400
10.900
11.400
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
Outdoor Air Temperature (°C)
Current
(A)
0.770
0.820
0.870
0.920
0.970
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa
)