9
ENGLISH
CARE & CLEANING
■ Washing Instructions
• Do not use benzene, thinner or
scouring powder.
• Use only soaps (
≃
pH7) or neutral
household detergent.
• Do not use water hotter than 40°C.
• Wipe the unit gently with a soft, dry
cloth.
INDOOR UNIT
• Air fi lters cleaning is needed every
two weeks.
• Replace any damaged fi lters.
Part no: CWD001137 (Left)
CWD001138 (Right)
AIR FILTER
• It is recommended to clean this fi lter
every 6 months.
• Replace the fi lter every 3 years or
replace any damaged fi lters.
Part no: CZ-SA13P
SUPER ALLERU-BUSTER
Ionizer cleaning is recommended
every 6 months.
IONIZER
■ Hints
• Clean the fi lter regularly for best
performance and to reduce power
consumption.
• Please consult your nearest dealer
for seasonal inspection.
Vacuum the super
alleru-buster fi lter.
Vacuum, wash and
dry the frame.
Remove
Raise and pull to remove.
Wash and dry.
Vacuum, wash and dry.
Clean with cotton
bud.
Wipe gently.
Remove
Remove
IONIZER
IONIZER
AIR FILTER
AIR FILTER
FRONT PANEL
FRONT PANEL
SUPERSONIC AIR
SUPERSONIC AIR
PURIFYING DEVICE
PURIFYING DEVICE
INDOOR
INDOOR
UNIT
UNIT
Switch off the power supply
Switch off the power supply
before cleaning
before cleaning
■ For extended non-use
• Activate heating for 2~3 hours to thoroughly dry the unit.
• Turn off the power supply and unplug.
• Remove the remote control batteries.