7.1. Parts Identification.
7.1.1. Vertical Airflow Direction Vane.
Airflow direction adjustment Up-and-Down.
The vertical airflow direction vane may
be positioned to deflect the air upward,
downward or straight on.
7.1.2. Ventilation Lever.
When the slide lever is in the:
“OPEN” position, the ventilation door
opens to allow air, smoke and odors to
be expelled from the room.
“CLOSE” position, the ventilation door is
closed and the air inside the room is
circulated and conditioned.
7.1.3. Operating Conditions.
Use the air conditioner under the following conditions:
Operating temperature range.
Indoor side Indoor side Outdoor side Outdoor side
D.B.T. W.B.T. D.B.T. W.B.T.
Maximum
Temperature
32°C 23°C 43°C 26°C
Minimum
Temperature
21°C 15°C 21°C 15°C
D.B.T.: Dry Bulb Temperature
W.B.T.: Wet Bulb Temperature
Note: Humidity may exceed 90%.
Continuous operation at over 90% high humidity may
create condensation and result in water drops on the
intake and outlet vanes.