5-11
Troubleshooting
Code Item Function (Factory setting)
13 Auto off timer 0: No power saving 1 (FP-7718)
1: 30 m 2: 60 m 2 (FP-7722/
3: 1.5 hr 4: 3 hr 7728/7735)
5: 4 hr
26 Duplex unit 0: Cancellation of duplex unit 1
(except FP-7718) 1: Duplex unit installation
automatically discriminated
27 Total copy count 0: Does not count up 0
In case of mis-feed in 1: Count up
second side copy for
two side copy, copy number
is/not counted.
(except FP-7718)
28 Total copy count 0: Does not count up 0
Checking double feed 1: Count up
by comparison between
in/out copies.
(except FP-7718)
38 Duplex unit initial 0: Does not select 1
mode setting 1: 1 sided to 2 sided
(except FP-7718) 2: 2 sided to 2 sided
3: Book to 2 sided
51 2 in 1 mode copy ratio 0: Full size 1
setting (except FP-7718) 1: Reduction
53 Auto shift (except FP-7718) 0: No auto shift 0
(Duplexing) 1: Auto shift
65 ETP system operation cycle Number of copies for operating timing of 1
(Refresh cycle) Refresh mode.
(FP-7728/7735) 0: 500 1:1,000
2:1,500 3:2,000 (copies)
71 Preventive maintenance 0: No indication 1
(Duplex unit) 1: Indication
(except FP-7718)