3-12
(2) Adjustment of in-bin paper detecting sensor
Remove all the paper from the bin unit.
1
Remove the right cover and set the dip switch
on the sorter controller PCB as shown.
(SW3: FA-S620, SW1:FA-S660)
2
3
Press the manual staple key.
4
Check the lighting condition of the manual
staple key.
Kept ON: Adjustment completed.
Blinking: Improper adjustment.
•Turn OFF and ON the power
switch of the copier.
Check the installation condition
of the sensor and repeat the
procedure of step 3.
5
Turn OFF all the dip switch
(SW3: FA-S620, SW1:FA-S660)
1
ON
23456
1
ON
23456
FA-S620