5
4 Inverter Warnings
The inverter circuit board supplies the magnetron tube with a very high voltage (4000 volts).
Danger
The inverter circuit board operates at high voltages
and high temperatures.
The Inverter PCB
Operates at a very high voltage and current.
Has an aluminium heat sink which becomes very
hot.
Has capacitors in the circuitry that hold a high volt-
age charge even when the oven is not operating.
Warning
Do not touch the high voltage circuit. When replac-
ing the board care must be taken to avoid possible
electric shock.
Do not touch the aluminium heat sink as it is part of
the high voltage circuit and becomes very hot.
Do not attempt to repair the inverter PCB, this
can be very dangerous. Replace the high volt-
age inverter circuit as a complete unit.
Do not adjust or tamper with the pre-set volume on
the inverter board. It is very dangerous to adjust
this pre-set without proper test equipment.
Do not operate the microwave oven when the
inverter grounding plate and fixing screw is loose.
It is very dangerous to operate the inverter circuit
board without a proper ground connection.
figure 1Assembly of the inverter circuit board
HEAT SINK
RECTIFIER BRIDGE
CHOKE COIL
SAND BAR RESISTOR
CURRENT TRANSFORMER
HIGH VOLTAGE TRANSFORMER
PRESET VOLUME *4
(DO NOT ADJUST)
FILM CAPACITORS
HIGH VOLTAGE
DIODES
HIGH VOLTAGE
CAPACITORS
CN 703
CN 701
CONTROL BOARD
WITH CUSTOM IC
PHOTOCOUPLER
DO NOT TOUCH
HOT/HIGH VOLTAGE *2
HIGH VOLTAGE AREA *1