Operating Instructions
Air Conditioner
ENGLISH
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
WEB-ACXF55-28650-EN
Wall Mounted
(Type K3)
Model No.
INDOOR UNIT
Wall Mounted
(Type K3)
S-3650PK3E
S-6010PK3E
OUTDOOR UNIT
Single Split
See page 12.
OI_00_321038_EN.indb 1 2020/10/27 10:53:15

Questions and Answers

Overview

This document provides operating instructions for a Panasonic air conditioner, specifically the Wall Mounted (Type K3) indoor unit models S-3650PK3E and S-6010PK3E, and various Single Split outdoor units.

Function Description

The air conditioner is designed to provide comfortable room conditions through cooling and heating operations. It incorporates a biocidal product that generates ionized air (nanoe™ X) to deactivate bacteria and viruses, and inhibit mold growth. The nanoe™ X function operates automatically upon purchase, generating negative ions to create a healthier environment, reduce odors, and constrain the propagation of mold and bacteria.

An internal drying function is activated when cooling or drying operations stop (after at least 5 minutes of operation) to suppress mold proliferation inside the unit (airflow passage, fan, heat exchanger). This process runs for a maximum of 90 minutes. In "DRY" operation, the outdoor unit cycles on and off automatically once the room temperature reaches the set level. If the room temperature is likely to reach the set level, the fan speed is automatically set to "breeze" (light wind). The unit also features an emergency operation mode for temporary use if the remote controller is broken, has dead batteries, or is lost.

Important Technical Specifications

Indoor Unit (Wall Mounted Type K3):

  • Model Names: S-3650PK3E, S-6010PK3E
  • Power Source (Europe): 220-230-240 V~ 50 Hz
  • Cooling Capacity:
    • S-3650PK3E: 3.6 kW (12,300 BTU/h) to 6.1 kW (20,800 BTU/h)
    • S-6010PK3E: 7.1 kW (24,200 BTU/h) to 9.5 kW (32,400 BTU/h)
  • Heating Capacity:
    • S-3650PK3E: 4.0 kW (13,600 BTU/h) to 7.0 kW (23,900 BTU/h)
    • S-6010PK3E: 8.0 kW (27,300 BTU/h) to 9.5 kW (32,400 BTU/h)
  • Cooling/Heating Electric Power Input (nanoe™ X "OFF"): 0.020 kW to 0.075 kW
  • Sound Pressure Level (High/Medium/Low):
    • S-3650PK3E: 35/31/27 dB(A) to 47/44/40 dB(A)
    • S-6010PK3E: 47/44/40 dB(A) to 49/45/41 dB(A)
  • Sound Power Level (High/Medium/Low):
    • S-3650PK3E: 51/47/43 dB(A) to 63/60/56 dB(A)
    • S-6010PK3E: 63/60/56 dB(A) to 65/61/57 dB(A)
  • Unit Dimensions (H×W×D): 302×1,120×236 mm
  • Net Weight: 13 kg to 14 kg
  • Operation Condition Temperature Range:
    • Cooling mode: 18°C~32°C DB
    • Heating mode: 16°C~30°C DB

Outdoor Units (Single Split, R32 Refrigerant):

  • Power Source (Europe): 220-230-240 V~ 50 Hz or 380-400-415 V 3N~ 50 Hz
  • Cooling Capacity: 3.6 kW (12,300 BTU/h) to 14.0 kW (47,800 BTU/h)
  • Heating Capacity: 4.0 kW (13,600 BTU/h) to 16.0 kW (54,600 BTU/h)
  • Sound Pressure Level (Cooling/Heating): 43/44 dB(A) to 56/56 dB(A)
  • Sound Power Level (Cooling/Heating): 62/64 dB(A) to 74/74 dB(A)
  • Unit Dimensions (H×W×D): 619×824×299 mm to 1,416×940×340 mm
  • Net Weight: 32 kg to 99 kg
  • Operation Condition Temperature Range:
    • Cooling mode: -15°C~46°C DB (Type 71), -15°C (-20°C)* ~46°C DB (Type 100, 125, 140)
    • Heating mode: -20°C~24°C DB
    • It is possible to operate at -20°C only in computer rooms with piping length of 30m or less.

Usage Features

  • Remote Control: The unit can be operated using optional wireless (CZ-RWS3) or wired (CZ-RTC4, CZ-RTC5B, CZ-RTC6*) remote controllers.
  • Power On/Off: The unit should be turned on and off using the ON/OFF operation button on the remote controller, not the power mains switch.
  • Emergency Operation: In case of remote controller failure, the emergency button on the indoor unit allows temporary operation in AUTO mode, with a set temperature of 24°C and high fan speed.
  • Energy Saving Tips: Avoid blocking air intake/outlet, use sunshades during cooling, keep air filters clean, and keep windows/doors closed to prevent conditioned air from escaping.
  • Defrosting: The unit may automatically initiate defrosting to melt frost from the outdoor unit. During this process, the indoor fan may stop or run at a very slow speed.
  • Power Failure Recovery: The unit automatically resumes operation with previous settings after a power failure.

Maintenance Features

  • Air Filter Maintenance: Air filters should be cleaned when the "Filter" indicator appears on the display, or frequently in dusty/oily environments (recommended every two weeks). Filters should be gently washed with water, dried in the shade, and replaced if damaged.
  • Cleaning Instructions: Use a soft cloth for general cleaning. For dirtier surfaces, a cloth moistened with water is recommended. Avoid using solvents, harsh chemicals, hot water (above 40°C), benzene, thinner, or scouring powder on plastic parts. Be cautious of sharp metal edges and fins.
  • Professional Cleaning: The internal coil and other components of the outdoor unit should be cleaned periodically by a dealer or service center. Users should not attempt to clean inside the indoor or outdoor units.
  • Troubleshooting: The manual provides a comprehensive troubleshooting guide for common issues like noise, odors, water accumulation, fog, fan operation, airflow direction, and unit malfunction.
  • Reporting Malfunctions: If the unit malfunctions and troubleshooting steps do not resolve the issue, users are advised to stop operation, turn off power, and contact their dealer, reporting the serial number and symptom. Self-repair is not recommended.

Panasonic K3 Specifications

General IconGeneral
BrandPanasonic
ModelK3
CategoryAir Conditioner
LanguageEnglish