The above values are the default values.
2.4.4. SERVICE FUNCTION TABLE
Code Function Set Value
Effective
Range
Default Remarks
501 Pause time set X 100
msec
001~600 030 ----------
502 Flash time X 10 ms 01~99 70 ----------
503 Dial speed select 1:10 pps 2:
20 pps
1, 2 1 ----------
520 CED frequency select 1:2100 Hz
2:1100 Hz
1, 2 1
See Symptom/
for long distance and
calls in THE UNIT CAN
CANNOT EITHER TRANSMIT/
RECEIVE LONG DISTANCE
INTERNATIONL
().
521 International mode select 1:ON 2:
OFF
1, 2 1
See Symptom/
for long distance and
calls in THE UNIT CAN
CANNOT EITHER TRANSMIT/
RECEIVE LONG DISTANCE
INTERNATIONL
().
522 Auto standby select 1:ON 2:
OFF
1, 2 1 The resolution reverts to the
when transmission is
523 Receive equalizer select
1: 0 km / 2:
1.8 km / 3:
3.6 km / 4:
7.2 km
1~4 1 Set RX equalizer to
524 Transmission equalizer
select
1: 0 km / 2:
1.8 km / 3:
3.6 km / 4:
7.2 km
1~4 1
550 Memory clear: To reset the value to the default one,
except the top margin (853) and left margin (854).
"START" input
551 ROM check
See TEST FUNCTIONS().
552 DTMF single tone test 1:ON 2:
OFF
1, 2 2
See TEST FUNCTIONS().
553 Monitor on FAX
communication select
1:OFF 2:
PHASE B 3
:ALL
1~3 1 Sets whether to monitor the
signal with the unit's
FAX communication or not.
554 Modem test
See TEST FUNCTIONS().
555 Scan check
See TEST FUNCTIONS().
556 Motor test 0
See TEST FUNCTIONS().
116