Items
Adjustment
Point
Procedure*
(L) Sensitivity
Receiver
Confirmation
- Follow steps 1 to 4 of (I) above.
5. Set DECT tester power to -88dBm.
6. Confirm that the BER is < 1000ppm.
(M) Timing
Confirmation
- Follow steps 1 to 4 of (I) above.
5. Confirm that the Timing accuracy is < ± 2.0ppm.
(N)
*
RSSI Level
Confirmation
- Follow steps 1 to 4 of (I) above.
5. Set DECT tester power to -88dBm.
6. Execute the command "readrssi"
7. Confirm: 25 < returned value < 43 (hex) (0x34 ± F (hex))
46