16. RF SPECIFICATION
16.1. Base Unit
Item Value Refer to -. *
TX Power More than 20 dBm ~ 25
dBm
Adjustment (Base Unit) (H)
Modulation 340 kHz/div ~ 402 kHz/
div
Adjustment (Base Unit) (I)
Data type:
Frequency Offset -50 kHz ~ +50 kHz
Adjustment (Base Unit) (J)
RX Sensitivity < 1000 ppm
Adjustment (Base Unit) (K)
Timing Accuracy < ± 2.0 ppm Adjustment (Base Unit) (L)
RSSI Level 0x34 hex ± F hex Adjustment (Base Unit) (M)
* : Refer to Adjustment (Base Unit) ()
16.2. Handset
Item Value Refer to -. **
TX Power More than 20 dBm ~ 25
dBm
Adjustment (Handset) (I)
Modulation 340 kHz/div ~ 402 kHz/
div
Adjustment (Handset) (J)
Data type:
Frequency Offset -50 kHz ~ +50 kHz
Adjustment (Handset) (K)
RX Sensitivity < 1000 ppm
Adjustment (Handset) (L)
Timing Accuracy < ± 2.0 ppm Adjustment (Handset) (M)
RSSI Level 0x34 hex ± F hex Adjustment (Handset) (N)
** : Refer to Adjustment (Handset) ()
17. HOW TO CHECK THE HANDSET SPEAKER
1. Prepare the digital voltmeter, and set the selector knob to ohm
meter.
2. Put the probes at the speaker terminals as shown below.
48