Pin Description I/O Hi Hi-z Remarks
89 Power Select D.O Low Power - -
90 LCD_SEGMENT D.O Active - -
91 LCD_SEGMENT D.O Active - -
92 LCD_SEGMENT D.O Active - -
93 LCD_SEGMENT D.O Active - -
94 LCD_SEGMENT D.O Active - -
95 LCD_SEGMENT D.O Active - -
96 LCD_SEGMENT D.O Active - -
97 LCD_SEGMENT D.O Active - -
98 LCD_SEGMENT D.O Active - -
99 LCD_SEGMENT D.O Active - -
100 LCD_SEGMENT D.O Active - -
27. EEPROM LAYOUT (BASE UNIT)
27.1. Scope
The purpose of this section is to describe the layout of the EEPROM (IC1) for the KX-TCD430
Base Unit.
The EEPROM contains hardware, software, and user specific parameters. Some parameters are
set during production of the base e.g. crystal frequency adjustment at address 0000 and 0001,
some are set by the user configuration.
27.2. Introduction
The base unit uses a 32K bit serial EEPROM (IC1) for storing volatile parameters. All parameters
are set up before the base leaves the factory. Some of these are vital for the operation of the
hardware so a set of default parameters is programmed before the actual hardware fine-tuning
can be initiated. This document lists all default settings with a short description.
In the tables below values in a range that are similar are not repeated; i.e. Address 00 to 01
contains the value 00 simply means that the value 00 is repeated in all addresses in the range.
All values in this document are in hexadecimal notation.
Type Name Description
D default The EEPROM location is preset to the Default value by the eeprom
default
A adjust
The EEPROM location is set during the production test and should not
be
overwritten. The value is set by the eeprom default loader only if the
location
contains all 1’s (byte: 0xFF, word FFFFh), i, e. it has never been set.
- EEPROM location which is not set at all.
Country
Setting
x Default - no specific country setting, so revert to default value