5
--
4
-
CAUTION
Do not subject the brushless amplier, motor
or shaft to high impact.
The failure could result in malfunction.
If trip occurs, remove the causes of the trip and
secure the safety before restarting.
The failure could result in injuries.
Execute the trial-operations with the motor xed
and a load unconnected. Connect a load to the
motor after the successful trial-operations.
The failure could result in injuries.
Use the specied voltage on the product.
The failure could result
in electric shocks, injuries, or re.
Install a safety device against idling or locking
of gear head, and leakage of grease.
The failure could result in injuries,
damages, and contaminations.
Do not modify, dismantle or repair the product.
The failure could result
in electric shocks, injuries, or re.
Do not block the heat dissipation hole.
The failure could result
in electric shocks, or re.
Maintenance and check must be performed by
an expert.
The failure could result
in injuries and electric shock.
Conduct proper installation according to
product weight or rated output.
The failure could result
in injuries, or damages.
Use the motor and amplier with the specied
combination.
The failure could result in re.
Ambient temperature of installed motor and
amplier should be under permittable one.
The failure could result in damages.
This product should be treated as an industrial
waste when it is disposed.
Be sure to turn off power when not using it for
a prolonged time.
The failure could result in injuries due
to unintentional operation.
Introduction/ Checking the model
After unpacking
• Make sure that the model is what you have ordered.
• Check whether the product has been damaged or not during transportation.
If any deciency should be found,
contact the dealer store where you bought this product.
Checking the model of Amplier and Motor
This amplier is designed for use in combination with a motor to be specied by us.
Check a name of series, rated output, voltage specications you wish to use
You must not use any other combinations than those listed below:
Standard
Voltage Out put Amplier Type Applicable Motor
Single phase AC100 to 120 V
50 W MBEK5A1BCV MBMS5AZBL
□
100 W MBEK011BCV MBMS011BL
□
200 W MBEK021BCV MBMS021BL
□
Single phase/3-phase AC200 to 240 V
50 W MBEK5A5BCV MBMS5AZBL
□
100 W MBEK015BCV MBMS012BL
□
200 W MBEK025BCV MBMS022BL
□
400 W MBEK045BCV MBMS042BL
□
3-phase AC200 to 240 V
750 W MBEK083BCV MBMS082BL
□
* Sufx of “
□
” in the motor model
represents shape of shaft.
Shaft
Round Keyway, center tap D-cut
Oil seal
without A S N
with C U Q
Checking the model of brushless amplier
Nameplate
Safety Precautions
Important
Do not frequently turn on and off the master
power source.
The failure could result in malfunction.
Do not place any obstacle that blocks ventilation
around the brushless amplier and the motor.
The failure could result in burns or re.
Model No.
Voltage
INPUT OUTPUT
Phase
F.L.C
Freq.
Power
200-240 V
3ø
4.0 A
50/60 Hz
0-240 V
3ø
3.6 A
0-267 Hz
750 W
Ser.No.
P13030001
BRUSHLESS AMPLIFIER
MBEK083BCV
Made in China 20130301
合格
Model name
input/output voltage
input/output phase
Rated
input/output current
input/output
Frequency
Rated output
Ex.:
P13030001*
Production Date
Ex.:
20130301
Consecutive
number
Month of production
Year of production
(Lower 2 digits of AD year)
day of Production
month of Production
year of Production (AD year)
Check the Model Name
Input power supply 1: Single phase AC100 to 120 V
3: 3-phase AC200 to 240 V
5: Single phase/3-phase AC200 to 240 V
V: speed control
Function 1
B: with circuit for regenerative resistor
Function 2 C: RS485 communication,
Signal input/Sink type (NPN transistor)
Output
5A: 50 W
01: 100 W
02: 200 W
04: 400 W
08: 750 W
KV Series motor drive