Substance
Influent Challenge
Concentration
Average
Reduction
Reduction
Requirement
Max Permissible Product
Water Concentration
Carbamazepine 1,400 ng/ L ± 20% 98.4 % N/A 200 ng
DEET 1,400 ng/ L ± 20% 98.6 % N/A 200 ng
Metolachlor
1,400 ng/ L ± 20% 98.2 % N/A 200 ng
Trimethoprim
140 ng/ L ± 20% 96.4 % N/A 20 ng
Linuron 140 ng/ L ± 20% > 96.5 % N/A 20 ng
TCEP 5,000 ng/ L ± 20% > 98.1 % N/A 700 ng
TCPP 5,000 ng/ L ± 20% 98.2 % N/A 700 ng
Phenytoin 200 ng/ L ± 20% > 94.4 % N/A 30 ng
Ibuprofen 400 ng/ L ± 20% > 95.4 % N/A 60 ng
Naproxen 140 ng/ L ± 20% > 97.5 % N/A 20 ng
Estrone 140 ng/ L ± 20% > 95.2 % N/A 20 ng
Bisphenol A 2,000 ng/ L ± 20% 99.0 % N/A 300 ng
Nonyl phenol 1,400 ng/ L ± 20% > 96.4% N/A 200 ng
Microplastics,
particles 0.5
to < 1μm
At lease 10,000
particles/ ml
99.7% ≥ 85% N/A
Operation Conditions
Capacity 1,136 L (300 gal)
Function Chemical / Mechanical
Usage Life 6 months
Flow Rate 1.9 lpm (0.5 gpm)
Temperature 2 ~ 38 °C (35 ~ 100 °F)
Pressure 206 ~ 861 kPa (30 ~ 125 psi)
System model: ARBHBA300020
Replacement Cartridge: ARAHFA105010
EPA Number: EPA Est No.94813-KOR-1
(NSF/ANSI Standard 53 Certied to reduce Cyst
by mechanical means.)
Manufactured by Microlter Co.,Ltd.
162-1, Sansu, Deoksan, Jincheon, Chung-Buk
27856, Korea.
Made in Korea
Tel no.: T: 82-43-531-7021~5 /F: 82-43-530-5499
Remark
● Systems must be installed and operated in accordance with manufacturer's recommended
procedures and guidelines. Follow any and all local plumbing codes and requirements.
Some local codes may require the use of a licensed plumber or a certied installer when
disrupting a potable water line.
● Failure to follow instructions may result in voidance of warranty.
● Change the filter cartridge at least every 6 months.
● To reduce the risks associated with water leakage, which, if not avoided, may result in
property damage - check with your plumbing professional to verify that water pressure is
less than 827 kPa (120 psi).
Performance Data Sheet For Filter System Model: ARBHBA300020
55