EasyManua.ls Logo

Panasonic Omnivision PV-9661 - Page 24

Panasonic Omnivision PV-9661
407 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
file:///E:/PV-9661_PV-9662/SVC/s0401020203.html
3. Place Mechanism Chassis and Cassette Up Ass´y as shown.
4. Secure the Extension Cables with tape as shown. When recording, cover the Safety Tab SW.
with masking tape to turn this SW. on.
Note:
To avoid damaging the connectors on Main C.B.A., it is necessary to secure connectors with
tape as shown.
5. Set Mode Select SW. on the Main C.B.A. to Service Position.
6. Plug the AC plug into an AC outlet.
7. Insert a cassette.
The power comes on, the tape is fully loaded, and the unit goes into the STOP Mode.
8. Place a jumper between TP6001 and GND to place the unit in Service Mode.
file:///E:/PV-9661_PV-9662/SVC/s0401020203.html (2 z 4) [2006-01-28 11:09:00]