6.2 Piping position
CAUTION: THE PIPING CAN BE LEAD OUT FROM LEFT SIDE OR REAR LEFT.
When routing the piping and wiring from the left side of the unit, removal of the chassis cut-outs is
necessary.
1. Remove cut-out 1 when routing the wiring only;
2. Remove both cut-out 1 and 2 when routing both the wiring and piping.
Take out the piping from body case, wrap the piping electric wire, water pipe with tape and pull them through the piping hole.
L - Left
LRLeft rear
1. Inlet water side pipe
2. Outlet water side pipe
3. Inlet side piping insulation
4. Final wrapping
5. Water drainage pipe
6. Outlet side piping insulation
6.3 Mounting slots
Hinge the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm enough.
Please note: the height of the installed location should be 2,5 m or more from the floor.
A Fixing hook
BMounting plate
C Mounting board