Chapter 7 Appendix — Technical information
ENGLISH - 143
r Received data
Header Data section
Termination
symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length
1 byte 1 byte Undened length 1 byte
r Error response
String Details
Termination
symbol
Message
“ERR1” Undened control command
(CR)
0x0d
“ERR2” Out of parameter range
“ERR3” Busy state or no-acceptable period
“ERR4” Timeout or no-acceptable period
“ERR5” Wrong data length
“ERRA” Password mismatch
Data length
4 bytes ― 1 byte
Control command
The following table lists the commands that can be used to control the projector using a computer.
r Projector control command/query command
Command Details
Parameter/response
string
Remark (parameter)
PON Power on ―
To check if the power is on, use the “Power supply status query”
command.
POF Power standby ―
QPW
Power supply status
query
000
001
STANDBY status
Power on status
IIS Input/mode selection
HD1 HDMI
MV1 MEMORY VIEWER
MC1 MIRRORING
PA1 Panasonic APPLICATION
SI1 SIGNAGE
OLP
Light source power
setting
0 NORMAL
QLP
Light source power
setting query
1 ECO
QST Runtime query 00000 - 99999 In hours
OSH AV mute 0 AV mute function off
QSH AV mute status query 1 AV mute function on
AUU Volume up ― ―
AUD Volume down ― ―