1. Press and hold STOP, PLAY, and VOL DOWN buttons on the unit
together over 5 seconds with no cassette inserted.
The adjustment overlay will appear to Enter EVR Adjustment mode.
Fig. 5-1
2. Set the Default value of all Control functions using a remote
control as shown in "Memory IC Reference Table."
Note:
For Selecting Control functions and setting Default value, refer to "
How to enter EVR adjustment mode" and "HOW TO ENTER EVR
PG SHIFTER ADJUSTMENT MODE" in ELECTRICAL
ADJUSTMENT procedures.
Fig. 5-2
3. Press and hold STOP, PLAY, and VOL DOWN buttons on the unit
together over 5 seconds again or press the POWER button OFF to
release EVR Adjustment Mode.
The Default value will be written to Memory IC (IC6004).