2. X-RADIATION
WARNING :
1. The potential source of X-Radiation in TV sets is the High Voltage
section and the picture tube.
2. When using a picture tube test fixture for service, ensure that the
fixture is capable of handling 25.0 kV (For model with 13 inch CRT)
or 30.0 kV (For model with 20 inch CRT) without causing X-
Radiation.
NOTE :
It is important to use an accurate periodically calibrated high
voltage meter.
1. Reduce the brightness to minimum.
2. Set the SERVICE switch to SERVICE .
3. Measure the High Voltage. The meter reading should indicate 23.5
kV±1.5 kV (For model with 13 inch CRT) or 28.5 kV±1.5 kV (For
model with 20 inch CRT).
If the meter indication is out of tolerance, immediate service and
correction is required to prevent the possibility of premature
component failure.
4. To prevent an X-Radiation possibly, it is essential to use the
specified picture tube.
HORIZONTAL OSCILLATOR DISABLE CIRCUIT TEST
SERVICE WARNING :
The test must be made as a final check before set is returned to the customer.
1. With the rear cover removed, supply about a 90 V AC power
source to the set, turn on the set.
2. Set the customer controls to normal operating positions.
5