Symptom of Misadjustment:
The picture is too white or too black.
Test Point :
----------
Adjustment :
SUB BRIGHT (EVR)
Specification :
Refer to descriptions below.
INPUT :
----------
Mode :
STOP
1. Do not input any signal to the unit.
2. Set INPUT SELECT item to LINE in SET UP TV menu to display
black screen.
3. Select SUB BRIGHT in EVR adjustment mode, and adjust so that
the black screen starts to turn grey (lighting only).
7.4. TEST POINTS AND CONTROL LOCATION
83