DIAL THREADING
1. Remove chasis from cabinet (Refer to 2. Disassembly and Main
Component Replacement Procedures and Operational Check)
2. Turn dial drum to fully counter-clockwise. (Turn dial gear to fulley
clockwise.).
3. Route dial cord in ordered character (1-6), turn 3 times at Tuning
Shaft.
4. Cement dial cord ends.
DIAL THREADING
1. Turn dial drum to fully counter-clockwise. (Turn dial drum to fully
clockwise.)
2. Set dial pointer to start point (0) of dial scale.
3. Attach dial cord to dial pointer.
8. Type Illustrations of ICs, Transistors & Diodes
9. Parts Location and Replacement Parts List
Notes:
- Important safety notice:
Components identified by mark have special characteristics
important for safety.
Furthermore, special parts which have purposes of fire-retardent
(resistors), high-quality sound (capacitors), low noise (resistors),
etc are used.
When replacing any of these components, be sure to use only
manufacturers specified parts shown in the parts list.