EasyManua.ls Logo

Panasonic RX-DS45

Panasonic RX-DS45
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RX-DS45
*
Checking
Operations
of
Replaced
Traverse
Deck
(New
Traverse
Deck)
a)
Check
the
operations
described
below
on
the
traverse
deck
after
replacing
it.
*
Checking
Skip
Search
*
Checking
Using
Defect
Disc.
1.
Play
an
ordinary
musical
program
disc.
1.
Play
the
0.7
mm
biack
dot
and
the
0.7
mm
wedge
on
2.
Press
the
skip
button
to
check
for
normal
skip
search
the
defect
test
disc
(SZZP1054C)
and
verify
that
no
operation
(in
both
the
forward
and
reverse
directions).
sound
skip
or
noise
occurs.
2.
Play
the
middle
tracks
of
the
uneven
test
disc
*
Checking
Manual
Search
(SZZP1056C)
and
verify
that
no
sound
skip
or
noise
1.
Play
an
ordinary
musical
program
disc.
occurs.
2.
Press
the
manual
search
button
to
check
for
smooth
manual
search
operations
at
either
low
or
high
speed
(in
both
the
forward
and
reverse
directions).
b)
If
the
operations
are
normal,
CD
adjustment
are
not
required
when
the
traverse
deck
is
replaced.
Note:
CD
adjustments
are
required
in
the
cases
below.
(Mechanical adjustments
are
not
necessary.)
(See
item
2-7
on
pp.
41~45.)
eif
audio
is
not
played
back
continuously
or
noises
occur
after
step
(a)
is
excuted.
@{f
the
adjustment
VRs
(VR701~VR706)
were
rotated
before
the
traverse
deck
was
replaced.
eif
the
ICs
in
the
servo
circuit
or
adjustment
VRs
were
replaced.
Caution:
elt
is
very
dangerous
to
look
at
or
touch
the
laser
beam.
(Laser
radiation
is
invisible.)
With
the
unit
turned
“on”,
laser
radiation
is
emitted
from
the
pickup
lens.
Avoid
exposure
to
the
laser
beam,
especially
when
performing
adjustments.
Vorsicht:
eVermeiden
Sie
es,
in
den
Laserstrahl
zu
blicken
oder
inn
zu
beriihren.
(Laserstrahlen
sind
unsichtbar.)
Bei
eingeschaltetem
CD-Spieler
werden
Laserstrahlen
aus
der
Aufnahmelinse
abgestrahit.
Vermeiden
Sie
direkte
Aussetzung
von
Laserstrahlen,
insbesondere
wahrend
der
Einstellarbeiten.
Measuring
instruments
and
Speciai
Tools
e
Audio
frequency
(AF)
oscillator
Servo
gain
adjuster
(SZZP1017F
or
SZZP1094C-1)
eConversion
connector
(SZZP1032F)
Test
discs
@2
mm
allen
wrench
(SZZP1101C)
1,
Playability
test
disc
(SZZP1054C)
2.
Uneven
test
disc
(SZZP1056C)
As
to
the
replacement
of
the
following
parts,
refer
to
3.
Black
band
test
disc
(SZ22P1057C)
the
specified
sections
for
adjustment.
@Norma!
disc
@Dual-beam
oscilloscope
with
bandwidth
of
30
MHz
or
better
(with
EXT
trigger
and
1:1
probe).
@TEMPORARY
SETTING
OF
EACH
VR
@
ALIGNMENT
POINT
Please
refer
to
Circuit
Board
and
Wiring
Connection
Diagram
for
test
point
locations.
FOCUS
TRACKING
TRACKING
GAIN
GAIN
OFFSET
VR?
~—
vR
[vR705
|
VR706
TRACKING
BEST
BALANCE
EYE
1C
707
OFFSET
2
TRACKING
TRACKING
eaance
A706]
GAIN
1C701
VR7O2
{C705
or
require
readjustment,
temporarily
set
them
to
the
following
positions.
(crecre
VR
setting
if
any
of
the
trimmer
VRs
are
replaced
)
FOCUS
OFFSET
~A41—

Related product manuals