7-11
7
Item code Item Description
01
Filter sign ON time setting
(filter lifetime)
Changes the indoor unit filter lifetime when a high-performance filter or
other optional product is installed.
02
Degree of filter fouling
Reduces the filter sign ON time to 1/2 of the standard time (setting at the
time of shipping) for cases when filter fouling is more severe than normal.
Filter sign ON times for each model
Model
data
Model
Filter sign ON time
Standard Long-life
0001
4-Way Cassette
(U1)
xx2500 1250
0005
Lo
w Silhouette
Ducted (F1)
xx
xx
xx
750 0007 Ceiling (T2) xx
x
1500
0008 Wall Mounted (K1) 150 75
NOTE
x indicates that there is no corresponding filter.
indicates the filter sign ON time that is set at shipment.
High fouling: Set when
is selected for the degree of filter fouling (item code ).
noitpircseDmetIedoc metI
03
Central control address
Set when using a central control device.
Used when setting the central control address manually from the
remote controller.
04
Operating mode priority change Note (1)
NOTE
There are other methods to avoid control in which the mode selected first takes priority.
Methods of remotely controlling the operating mode
(1) Use the central functions of a central control device.
(2) Use a remote control relay PCB at the outdoor unit.
Standard
High
fouling
Standard
High
fouling
7-5. Simple Setting Items
Sec7.indd9 2012/02/2815:07:25
0036 Ducted (N1)
x
xx
SM830231-00Single欧州.indb11SM830231-00Single欧州.indb11 2014/06/2014:28:042014/06/2014:28:04