TH-L42S10M
30
8 Measurements and Adjustments
8.1. Voltage Chart of A Board
Set A-Board to a dummy set and check the satisfaction with the specified voltage as following table.
8.2. Voltage Chart of P Board
Set P-Board to a dummy set and check the satisfaction with the specified voltage as following table.
Power Supply Name Measurement Point Specification (V)
SUB1.2V TP5602 1.22 - 1.32
SUB1.8V TP5601 1.78 - 1.91
SUB3.3V TP5600 3.21 - 3.45
SUB9V TP5409 8.76 - 9.45
SUB5V TP5405 4.82 - 5.18
BT30V TP5482 29.3 - 31.5
Power Supply name Measurement Point Normal condition (V) Standby condition (V)
24V TPP034 24.0 ± 1.2 NO CARE
12V TPP033 12.0 ± 0.6 / -0.45 < 1.0
Audio Vcc TPP028 16.4 ± 0.7 < 3.0
STBY_6V TPP040 5.8 ± 0.3 5.8 ± 0.3