Operating Instructions
Air Conditioner
4-Way Cassette
(U1 type)
Low Silhouette Ducted
(F1 type)
Ceiling
(T2 type)
Model No.
INDOOR UNIT
4-Way Cassette
(U1 type)
S-36PU1E5A
S-45PU1E5A
S-50PU1E5A
S-60PU1E5A
S-71PU1E5A
S-100PU1E5A
S-125PU1E5A
S-140PU1E5A
Ceiling
(T2 type)
S-36PT2E5A
S-45PT2E5A
S-50PT2E5A
S-60PT2E5A
S-71PT2E5A
S-100PT2E5A
S-125PT2E5A
S-140PT2E5A
Low Silhouette Ducted
(F1 type)
S-36PF1E5A
S-45PF1E5A
S-50PF1E5A
S-60PF1E5A
S-71PF1E5A
S-100PF1E5A
S-125PF1E5A
S-140PF1E5A
OUTDOOR UNIT
Single Split
(Single-phase)
PE1 Type
U-50PE1E5
U-60PE1E5A
U-71PE1E5A
U-100PE1E5A
U-125PE1E5A
U-140PE1E5A
Single Split
(3-phase)
PE1 Type
U-71PE1E8A
U-100PE1E8A
U-125PE1E8A
U-140PE1E8A
Single Split
(Single-phase)
PEY1 Type
U-60PEY1E5
U-71PEY1E5
U-100PEY1E5
U-125PEY1E5
Single Split
(3-phase)
PEY1 Type
U-100PEY1E8
U-125PEY1E8
U-140PEY1E8
ENGLISH
2 ~ 9
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
FRANÇAIS
10 ~ 17
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et
conservez-le pour toute référence ultérieure.
ESPAÑOL
18 ~ 25
Antes de operar la unidad, lea atentamente estas instrucciones de
funcionamiento y guárdelas para futuras consultas.
DEUTSCH
26 ~ 33
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese
Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die
künftige Verwendung auf.
ITALIANO
34 ~ 41
Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e
conservarle come riferimento futuro.
NEDERLANDS
42 ~ 49
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en
bewaar ze voor toekomstig gebruik.
PORTUGUÊS
50 ~ 57
Antes de utilizar o aparelho, leia completamente este manual de instruções
e guarde-o para futuras referências.
EΛΛΗΝΙΚΆ
58 ~ 65
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες
χρήσης και διατηρήστε τις για μελλοντική αναφορά.
БЪЛГАРСКИ
66 ~ 73
Преди да започнете експлоатация на този уред, прочетете внимателно
тези инструкции и ги запазете, за да можете да правите справки с тях и
в бъдеще.
ENGLISH
FRANÇAIS
ESPAÑOL
DEUTSCH
ITALIANO
NEDERLANDS
PORTUGUÊS
EΛΛΗΝΙΚΆ
БЪЛГАРСКИ
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
F569616
OI00F569616EU.indb1OI00F569616EU.indb1 2014/02/289:30:582014/02/289:30:58
AMP Air Conditioning
www.ampair.co.uk | sales@ampair.co.uk

Other manuals for Panasonic U-60PE1E5A

Questions and Answers

  • R
    randywagnerAug 8, 2025
    Why is my Panasonic U-60PE1E5A Air Conditioner not cooling or heating properly?
    • J
      jamescontrerasAug 8, 2025
      If your Panasonic Air Conditioner isn't cooling or heating well, check if the air intake or outlet of the indoor and outdoor units is blocked with dust and remove any dust. You can also try setting the fan speed to “High” or “Strong”.
  • R
    rebecca05Aug 18, 2025
    What to do if my Panasonic U-60PE1E5A does not turn on?
    • T
      Teresa HarperAug 18, 2025
      If your Panasonic Air Conditioner isn't turning on, even though it's plugged in, first, press the power ON/OFF button on the remote controller. Also check the breaker. If the breaker is turned off, turn the power on. If the breaker has been tripped, consult your dealer without turning it on.
  • D
    Debra SanchezAug 28, 2025
    Why is my Panasonic U-60PE1E5A making noise?
    • I
      Ian BlackburnAug 28, 2025
      There are several reasons why your Panasonic Air Conditioner might be making noise. It could be due to the sound of refrigerant liquid flowing inside the unit, drainage water moving through the drain pipe, or temperature changes affecting the unit's parts. Indoor odor components, cigarette odor, and cosmetic odor accumulated in the air conditioner and its air is discharged. Also, if the unit inside is dirty, especially if it's been installed in a place with a lot of oil mist, it may require cleaning by a dealer. Other causes include defrost operation, smooth fan rotation, the fan drying the heat exchanger, horizontal wind flow during heating or defrost, flap movement, dust discharge, or operation checks.

Summary

Safety Precautions

Precautions for Use

Installation

Guidance on proper installation, including voltage checks and location considerations.

Wiring

Requirements for electrical wiring, grounding, and the need for a qualified electrician.

Operation Preparation

Instructions for preparing the unit for operation, including warm-up procedures.

Information for Users on Collection and Disposal of Old Equipment and Used Batteries

Guidelines for responsible disposal of electronic products and batteries according to regulations.

Names of Parts

INDOOR UNIT

Identification of components for various indoor unit types (U1, T2, F1).

OUTDOOR UNIT

Identification of components for various outdoor unit types (PE1, PEY1).

Operation Mechanism

Explanation of how the unit functions, including heating performance and defrosting.

Adjusting Airflow Direction

Using the timer remote controller

Instructions for adjusting airflow direction using the timer remote controller.

Using the wireless remote controller

Instructions for adjusting airflow direction using the wireless remote controller.

Recommended vertical airflow direction

Guidance on optimal vertical airflow settings for heating and cooling modes.

Adjusting the horizontal airflow direction

Instructions for manually adjusting the horizontal airflow vanes on T2 type units.

Adjusting airflow direction for multiple indoor units

Tips for Energy Saving

Recommendations for optimizing energy efficiency, such as filter cleaning and closing openings.

Maintenance

Indoor unit

Procedures for cleaning the indoor unit, including the air outlet flap.

Before Requesting Services

Troubleshooting guide for common issues before contacting a dealer.

Troubleshooting

Indoor unit

Diagnosing and resolving common noise, smell, and airflow issues with the indoor unit.

Outdoor unit

Troubleshooting common issues related to the outdoor unit operation.

Panasonic U-60PE1E5A Specifications

General IconGeneral
Cooling Capacity6.0 kW
Energy Efficiency Ratio (EER)3.21
RefrigerantR32
SCOP4.0
TypeSplit Type
Power Supply220-240 V, 50 Hz

Related product manuals