EasyManua.ls Logo

Panasonic U-60PZ3E5 - User Manual

Panasonic U-60PZ3E5
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operating Instructions
Air Conditioner
ENGLISH
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
WEB-ACXF55-27531-EN
Middle Static Pressure Duct
(Type F3)
<At horizontal installation>
<At vertical installation>
Model No.
INDOOR UNIT
Middle Static Pressure Duct
(Type F3)
S-3650PF3E
S-6071PF3E
S-1014PF3E
OUTDOOR UNIT
Single Split
See the page 11.
01_320325_Eng.indb 1 2020/01/24 14:35:41

Other manuals for Panasonic U-60PZ3E5

Questions and Answers

Summary

Safety Precautions

Product Information

Information required for addressing problems or questions about the air conditioner.

Precautions for Use

Installation

Guidelines for proper installation of the air conditioner unit.

Wiring

Requirements for electrical wiring and grounding of the unit.

Operation Preparation

Steps to prepare the unit for operation, including warm-up.

Tips for Energy Saving

Recommendations for efficient energy usage during operation.

Names of Parts

Indoor Unit Components

Identification and illustration of the indoor unit components.

Outdoor Unit Components

Identification and illustration of the outdoor unit components.

Optional Accessories

Optional accessories available for the air conditioner system.

Maintenance

Air Filter Maintenance

Instructions for maintaining and cleaning the air filter.

Operation Mechanism

Explanation of how heating, defrosting, and DRY modes function.

nanoe X Function

Troubleshooting

Before Requesting Services

Steps to check before contacting a dealer for issues like no operation or poor performance.

Connectable Outdoor Unit Lineup

Indoor Unit Specifications

Outdoor Unit Specifications

Single Split Outdoor Unit (R32)

Technical specifications for single split outdoor units, categorized by region and model.

Summary

Safety Precautions

Product Information

Information required for addressing problems or questions about the air conditioner.

Precautions for Use

Installation

Guidelines for proper installation of the air conditioner unit.

Wiring

Requirements for electrical wiring and grounding of the unit.

Operation Preparation

Steps to prepare the unit for operation, including warm-up.

Tips for Energy Saving

Recommendations for efficient energy usage during operation.

Names of Parts

Indoor Unit Components

Identification and illustration of the indoor unit components.

Outdoor Unit Components

Identification and illustration of the outdoor unit components.

Optional Accessories

Optional accessories available for the air conditioner system.

Maintenance

Air Filter Maintenance

Instructions for maintaining and cleaning the air filter.

Operation Mechanism

Explanation of how heating, defrosting, and DRY modes function.

nanoe X Function

Troubleshooting

Before Requesting Services

Steps to check before contacting a dealer for issues like no operation or poor performance.

Connectable Outdoor Unit Lineup

Indoor Unit Specifications

Outdoor Unit Specifications

Single Split Outdoor Unit (R32)

Technical specifications for single split outdoor units, categorized by region and model.

Overview

This document provides operating instructions for a Panasonic Middle Static Pressure Duct (Type F3) indoor unit, part of a commercial air conditioner system. It covers essential safety precautions, usage guidelines, maintenance procedures, and troubleshooting tips. The manual also details the nanoe™ X function, an air purification technology integrated into the unit.

Function Description

The Panasonic Middle Static Pressure Duct (Type F3) is an indoor unit designed for commercial air conditioning systems, specifically for single-split configurations. It is intended to provide comfortable room conditions by cooling or heating the air. The unit is typically installed horizontally in the ceiling with a rear-side air intake, connecting to an air outlet duct and grille.

A key feature of this air conditioner is the integrated nanoe™ X function. This technology generates negative ions (free radicals) from ambient air or water, which are then discharged into the room. The nanoe™ X function aims to create a healthier and cleaner environment by deactivating bacteria and viruses in the air and on surfaces, as well as inhibiting mold growth and reducing odors. This function operates automatically upon purchase, though it can be turned off if desired, with instructions provided in the remote controller manual. The effectiveness of nanoe™ X may vary depending on installation conditions.

The air conditioner also includes standard cooling and heating operations. During cooling, if the room temperature reaches the set level, the outdoor unit automatically cycles on and off, and the fan speed may reduce to a "breeze" setting. For heating, the unit utilizes outside air, and its performance may decrease in lower outdoor temperatures, potentially requiring an additional heating appliance. The system also incorporates a defrosting operation to melt frost that forms on the outdoor unit, during which the indoor unit fan may stop or run at a very slow speed until the heat exchanger warms up.

Usage Features

To ensure safe and efficient operation, users should adhere to several guidelines:

  • Installation: The unit must be installed by qualified technicians according to the provided Installation Instructions. It's crucial to verify that the electrical supply voltage matches the unit's nameplate. Avoid installing the unit in locations with smoke, combustible gas, extremely high temperatures (like greenhouses), or near excessively heat-generating objects. The outdoor unit should not be installed where salty sea water or sulphurous air (near a spa) can directly splash it, to prevent heavy corrosion.
  • Wiring: All wiring must comply with local electrical codes and be performed by a qualified electrician. Each unit requires proper grounding with an earth wire or through the supply wiring.
  • Power On: Before starting operation, turn on the main power supply 5 hours in advance for warm-up. For continuous use, leave the power mains ON. If the unit is not in use for a long time, disconnect the power by pulling the plug, switching off the breaker, or using the power disconnecting means.
  • Energy Saving: To optimize energy consumption, avoid blocking the air intake and outlet of the unit, as this impairs performance. During cooling, use sunshades, blinds, or curtains to prevent direct sunlight. Always keep windows, doors, and other openings closed to prevent conditioned air from escaping. Regularly clean the air filter, as a clogged filter reduces efficiency.
  • Remote Control: The system can be operated using various optional remote controllers, including Wireless, Timer, High-spec Wired, and Wired Remote Controllers. Users should refer to the specific operating instructions included with their remote controller for detailed guidance on operation and adjusting airflow direction. The remote controller display will show indicators for filter maintenance and the status of the nanoe™ X function.
  • Power Failure: In the event of a power failure while the unit is running, it will automatically resume operation with the settings that were active before the power interruption.

Maintenance Features

Regular maintenance is crucial for the longevity and optimal performance of the air conditioner:

  • Safety First: Before any cleaning or servicing, always turn off the air conditioner and disconnect the power to prevent electric shock or injury from rotating fan parts. Never pour water directly onto the indoor unit, as this can damage internal components and cause electric shock.
  • Cleaning: Avoid using solvents, harsh chemicals, or very hot water on plastic parts, as these can cause deformation or discoloration. Be cautious when cleaning metal edges and fins, as they can be sharp. For indoor units installed in high locations, use a firm stool or ladder.
  • Air Filter Maintenance: The air filter should be kept clean to maintain unit performance. The remote controller display will show a "Filter" indicator when maintenance is required. Users should consult their dealer or service center for air filter cleaning.
  • Professional Cleaning: The internal coil and other components of both the indoor and outdoor units require periodic cleaning by an authorized dealer or service center. Users should not attempt to clean these parts themselves.
  • Troubleshooting: The manual provides a troubleshooting guide for common issues such as unusual noises (streaming water, cracking), odors from discharged air, dewdrops, fog, fan operation after shutdown, dust discharge, and abnormal fan speeds. It also addresses issues related to the nanoe™ X display on the remote controller and non-operation of the unit. If the air conditioner does not work properly after checking these items, users should immediately stop operation, turn off the power, and contact their dealer, reporting the serial number and any error codes displayed on the remote controller (e.g., E, F, H, L, P in combination with numbers). Users are strongly advised not to attempt repairs themselves due to safety risks.
  • Storage: The appliance should be stored in a well-ventilated area free from continuously operating open flames or ignition sources. The room size should correspond to the specified room area for operation. If the appliance uses flammable refrigerants, the storage area must be constructed to prevent refrigerant leaks from stagnating, which could create a fire or explosion hazard.
  • Disposal: The unit and any used batteries should not be mixed with general household waste. They must be disposed of at applicable collection points in accordance with national legislation and EU Directives (2002/96/EC and 2006/66/EC) to ensure proper treatment, recovery, and recycling. Business users in the European Union should contact their dealer or supplier for disposal information. For countries outside the EU, local authorities or dealers should be consulted for correct disposal methods.

Panasonic U-60PZ3E5 Specifications

General IconGeneral
BrandPanasonic
ModelU-60PZ3E5
CategoryAir Conditioner
LanguageEnglish

Related product manuals