Operating Instructions
Air-to-Water Hydromodule + Tank
Operating Instructions
Air-to-Water Hydromodule + Tank
2-27
Thank you for purchasing Panasonic product.
Before operating the system, please read these operating instructions
thoroughly and keep them for future reference.
Installation Instructions attached.
Serial number and production year please refer to name plate.
Betjeningsvejledning
Luft-til-vand hydromodul + Tank
28-53
Tak, fordi du købte et Panasonic produkt.
Læs brugsanvisningen grundigt igennem før du benytter anlægget og
gem den til fremtidig brug.
Installationsvejledning vedhæftet.
For serienummer og produktionsår henvises der til typeskiltet.
Model No.
Indoor Unit
WH-ADC0309H3E5AN
Outdoor Unit
WH-UD03HE5-1
WH-UD05HE5-1
WH-UD07HE5-1
WH-UD09HE5-1
Indoor Unit
WH-ADC0916H9E8AN
Outdoor Unit
WH-UD09HE8
WH-UD12HE8
WH-UD16HE8
WH-UX09HE8
WH-UX12HE8
WH-UX16HE8
WH-UQ09HE8
WH-UQ12HE8
WH-UQ16HE8
ACXF55-21150
Manufactured by:
Panasonic AVC Networks Czech, s.r.o.
U Panasoniku 1, 320 84 Plzeň , Czech Republic

Other manuals for Panasonic WH-ADC0916H9E8

Questions and Answers

  • R
    Rhonda RuizSep 13, 2025
    Why is the Panasonic Heat Pump operation delayed after restarting?
    • W
      Whitney BakerSep 13, 2025
      The delay is a protection mechanism for the compressor.
  • A
    amy63Aug 25, 2025
    Why does my Panasonic Air Conditioner outdoor unit emit water or steam?
    • C
      Charles CordovaAug 25, 2025
      The emission of water or steam from your Panasonic Air Conditioner's outdoor unit is due to condensation or evaporation occurring in the pipes.
  • R
    Richard MichaelAug 25, 2025
    Why is my Panasonic WH-ADC0916H9E8 system hard to heat up?
    • B
      Barbara FosterAug 26, 2025
      Your Panasonic Heat Pump system may take longer to heat up if the panel and floor are heated simultaneously, which can decrease the warm water temperature and reduce heating ability. Also, low outdoor air temperature or a low preset water outlet temperature can extend the heating time. Check if the discharge outlet or intake inlet in the outdoor unit is blocked by obstacles like snow.
  • J
    Jennifer MorrisonSep 23, 2025
    Why is there a water flowing sound in my Panasonic WH-ADC0916H9E8?
    • D
      Daniel HubbardSep 23, 2025
      The water flowing sound you hear during operation is due to the refrigerant flow inside the Panasonic Heat Pump unit.
  • E
    emasseySep 14, 2025
    What to do if operation in HEAT/COOL mode is not working efficiently in Panasonic Heat Pump?
    • E
      Emily WalkerSep 14, 2025
      If your Panasonic Heat Pump's HEAT/COOL mode isn't working efficiently, make sure the temperature is set correctly. Close the panel heater/cooler valve. Also, check the outdoor unit and clear any obstructions from the air inlet and outlet vents.
  • L
    leeamandaSep 23, 2025
    Why does Panasonic WH-ADC0916H9E8 Heat Pump outdoor unit emits water or steam?
    • M
      Melinda LewisSep 23, 2025
      The water or steam emitted from the outdoor unit of your Panasonic Heat Pump is due to condensation or evaporation occurring in the pipes.
  • J
    John TorresSep 6, 2025
    Why is my Panasonic Air Conditioner backup heater automatically turned ON when it is disabled?
    • K
      Kara TranSep 7, 2025
      If the backup heater in your Panasonic Air Conditioner turns on automatically when disabled, it's due to the protection control of the indoor unit heat exchanger.
  • B
    Blake NelsonSep 7, 2025
    Why does loud refrigerant noise continue for several minutes in my Panasonic Air Conditioner?
    • T
      Terry TurnerSep 7, 2025
      The loud refrigerant noise in your Panasonic Air Conditioner is caused by protection control during de-icing operation when the outdoor temperature is lower than -10 °C.
  • R
    Ronnie JohnsonSep 23, 2025
    Why does my Panasonic Heat Pump start automatically?
    • C
      Carol TaylorSep 23, 2025
      Your Panasonic Heat Pump might be starting automatically because the sterilization timer has been set.
  • L
    Lynn PetersonAug 31, 2025
    Why is my Panasonic Air Conditioner outdoor unit not operating?
    • V
      Valerie JonesAug 31, 2025
      The Panasonic Air Conditioner outdoor unit might not operate due to the system's protection control when the outdoor temperature is outside of the operating range.