How to troubleshoot PFC control problems in a Panasonic WH-MDF06D3E5?
- JjessicaryanSep 12, 2025
If your Panasonic Heat Pump is experiencing PFC control issues, check the voltage at PFC.
How to troubleshoot PFC control problems in a Panasonic WH-MDF06D3E5?
If your Panasonic Heat Pump is experiencing PFC control issues, check the voltage at PFC.
What to do if my Panasonic WH-MDF06D3E5 displays an indoor water outlet temperature sensor abnormality?
If your Panasonic Heat Pump shows an indoor water outlet temperature sensor abnormality, you should check the water outlet temperature sensor.
What to do if my Panasonic Heat Pump shows outdoor defrost sensor abnormality?
If your Panasonic Heat Pump is showing an outdoor defrost sensor abnormality, you should check the outdoor defrost sensor.
What should I check if my Panasonic WH-MDF06D3E5 Heat Pump displays an indoor water inlet temperature sensor abnormality?
If your Panasonic Heat Pump shows an indoor water inlet temperature sensor abnormality, you should check the water inlet temperature sensor.
Why is my Panasonic Heat Pump system difficult to heat up?
A Panasonic heat pump system may be difficult to heat up if heating is operated together with floor heating or a panel heater simultaneously, which can lower the warm water temperature. Also, low outdoor air temperatures, a snow pile blocking the discharge outlet or intake inlet of the mono bloc unit, or a low water outlet set temperature can make it difficult to get warm.
What to do if my Panasonic Heat Pump has a pressure switch abnormality?
If your Panasonic Heat Pump has a pressure switch abnormality, check the pressure switch.
What to check for Outdoor Direct Current (DC) peak detection in Panasonic Heat Pump?
If your Panasonic Heat Pump is experiencing Outdoor Direct Current (DC) peak detection, check the outdoor PCB and the compressor.
What to do if my Panasonic Heat Pump is showing a back-up heater OLP abnormality?
If your Panasonic Heat Pump displays a back-up heater OLP abnormality, you should check the back-up heater OLP. This may continue for 60 seconds.
What should I check if my Panasonic WH-MDF06D3E5 displays a tank sensor abnormal error?
If your Panasonic Heat Pump displays a tank sensor abnormality, you should check the tank sensor. This may continue for 5 seconds.
What to do if my Panasonic Heat Pump displays an outdoor heat exchanger temperature sensor abnormality?
If your Panasonic Heat Pump is showing an outdoor heat exchanger temperature sensor abnormality, you should check the outdoor heat exchanger temperature sensor.
| Heating Capacity | 6.0 kW |
|---|---|
| Energy Efficiency Class (Heating) | A++ |
| Energy Efficiency Class (Cooling) | A+ |
| Refrigerant | R32 |
| Type | Air to Water Heat Pump |
| Power Supply | 230V / 50Hz |
| Operating Temperature Range (Heating) | -15 to +24 °C |
| Operating Temperature Range (Cooling) | +10 to +43 °C |