EnglishMenus
Menu Default Setting Setting Options / Display
6.3
Auto
Automatic switch from Heat to
Cool or Cool to Heat.
Outdoor temperatures for switching from Heat
to Cool or Cool to Heat.
Outdoor temp. for (Heat to Cool) /
Outdoor temp. for (Cool to Heat)
Outdoor temp. for (Heat to Cool)
15 °C
Set outdoor
temperature for
switching
from Heat to Cool.
Outdoor temp. for (Cool to Heat)
10 °C
Set outdoor
temperature for
switching
from Cool to Heat.
6.4
Tank
Setting functions for the tank.
Floor operation time (max) /
Tank heat up time (max) /
Tank re-heat temp. /
Sterilization
The display will show 3 functions at a time.
Floor operation time (max)
8:00
Maximum time for
oor operation
(in hours and minutes)
Tank heat up time (max)
1:00
Maximum time for
heating the tank
(in hours and minutes)
Tank re-heat temp.
-8 °C
Set temperature to
perform reboil of tank
water.