84
Aquarea air / water heat pump – design handbook 07 / 2014
Fastening of
the monobloc unit
Project Design
Planning heat source – air
Fastening of the monobloc unit
The monobloc unit must be mounted on one level, horizontal and on a
solid surface. Besides the weight of unit, also the weight of water must
be considered. Four anchoring bolts M12 are needed for fastening,
where the tightening force is minimum 15,000 N.
Minimum requirements for
anchoring the Monobloc unit
to the oor or a foundation
(left) or directly to a base
plate (right)
60
mm
300
mm
>
20
80
4
3
3
4
2
1
≈100
4
800
3
1
5
2
355
460
775
980
300
200
60
1
Base
2
Gravel
3
Strip foundation
or base plate
4
Anchor bolt
5
Drainage pipe
All dimensions in mm